Home water treatment

Test the water first, then size the equipment

Quick answer

16 calculators and 345 computed reference pages for softener sizing, salt and regeneration, whole house flow rate, filter life, reverse osmosis output and ultraviolet dose. Every figure is labeled as a published standard, a rule of thumb, or something that only comes off your own water test, because on this subject those three are not the same thing.

Start with a number you do not have yet

All 16 calculators

Two complete ladders, because there are two kinds of water

A city customer has a utility that treats water to a regulated standard and publishes a report every year at no charge. A well owner has no utility, no report and no operator, and nobody tests the water but them. Pushing both through one ladder would give bad advice to both, so there are two.

Look up a computed answer

Three kinds of number, labeled separately

Published figure

The grains per gallon to milligrams per liter conversion of 17.1. The USGS hardness classification. Resin exchange capacity at a stated salt dose. The NSF/ANSI standard numbers and what each one covers. EPA maximum contaminant levels and secondary standards. Federal maximum fixture flow rates. The NSF/ANSI 55 ultraviolet dose classes. These do not move because somebody disagrees with them.

Rule of thumb

Eighty gallons per person per day as a sizing figure. Regenerating about once a week. Adding three to five grains of compensated hardness per part per million of dissolved iron. Sizing a whole house filter by bathroom count. All taught everywhere, all useful for planning, and none of them published by any standards body.

From your own water test

Hardness, iron, manganese, pH, total dissolved solids, nitrate, bacteria. Nothing on this site supplies one of these and nothing here can override one. This is the pill that matters most, because sizing equipment for a number nobody measured is the most expensive mistake in the category.

There is a fourth category we handle by refusing to fill it in. Where no published figure exists, we say so. There is no EPA limit for hardness of any kind, because hardness is not a health contaminant. We publish no generic water volume per regeneration, because it is set by the control valve program and varies by more than a factor of two between units with the same nameplate. We publish no generic pressure drop, because every cartridge has its own published curve. A blank that says "not published" is a better answer than a number nobody can stand behind.

What is on the site

Everything published here
Section Pages What it is
Calculators 16 Every one shows its formula and labels the basis of every figure it prints.
Computed reference 345 Nine clusters generated from the same formulas the calculators use.
Spec sheets 49 Every figure each manufacturer publishes, with nothing estimated.
Guides, roundups and charts 130 Researched from published standards and owner-review consensus.
Complete systems 6 Two ladders of three tiers, every item priced and linked, in plumbing order.
Verified products 191 Every ASIN resolved live and every returned title read against the product claimed.

The safety part, which is not the fine print

Nothing here diagnoses your water or says a product makes it safe to drink. That is a laboratory result, not a property of a product. What this site does is describe what a contaminant is, what the published standard says about it, and what class of equipment is designed to address it.

Bacteria, nitrate, lead, arsenic and PFAS are not do it yourself topics. They are invisible and tasteless, so nothing tells you whether equipment has stopped working. The limits are legal figures rather than preferences, and lead does not even have a maximum contaminant level: it has an action level of 0.015 mg/L, which is a trigger for utility action rather than a safe concentration, and the health goal is zero. No filter pitcher addresses any of them. Talk to your local health department or a licensed water treatment professional first.

A certification covers a specific claim, not the whole unit. NSF/ANSI 42 is aesthetic effects such as chlorine taste and odor, and it is not a lead claim. 53 is health effects, claim by claim. 44 is softeners. 55 is ultraviolet, where Class A delivers 40 mJ/cm2 for water not known to be safe and Class B delivers only 16 as a supplement to water already considered safe. 58 is reverse osmosis. 372 is the lead content of a fitting rather than lead removal. The phrase "NSF certified" with no number attached tells you very little, and saying so is one of the more useful things this site does.

Get the water tested before you spend anything. On city water the Consumer Confidence Report your utility publishes every year is free and covers the regulated contaminants. On a private well only a certified laboratory test tells you what you have. Hardness is the one figure you can genuinely read at home in under a minute with a strip, so there is no reason to guess at it.

Get the complete water treatment shopping list

Every item in the starter, complete and premium systems for both city water and well water, with running totals, in one printable list. It opens with the test kit, because that is genuinely the first purchase. No charge.

One list, no sequence of daily emails, and you can leave at any time.